Add to Cart
Model | Morel R8 | |
Heating System | Number of heating zones | Top 8/Bottom 8 |
Number of cooling zones | 2 | |
Heating passage | 3600mm | |
Heating style | Hot air | |
Cooling style | Air Oven: Forced air; Nitrogen Oven: Water Chiller | |
Exhaust Volume | 10m³/min * 2 vanes | |
Conveyor System | Max. Width of PCB | 450mm |
Mesh belt width | 500mm | |
Conveyor Direction | L→R(or R→L) | |
Process height | 900±20mm | |
Conveyor type | Mesh and chain | |
Range of rail width | 0-450mm | |
Conveyor speed | 0-2000mm/min | |
Auto/manual Lubrication | standard | |
Fixed track | Front rail fixed(option: rear rail fixed) | |
Product clearance | Top and bottom 25mm | |
Control system | Power supply | 5 cables 3 phase 380V 50/60Hz |
Total consumption | 40kw | |
Startup consumption | 38kw | |
Steady consumption | 8KW | |
Ramp up time | About 20 mins | |
Temp. set-point range | Room temperature-300℃ | |
Temp. control method | PID close loop control & SSR driving | |
Temp. control precision | ±1℃ | |
Temp. deviation on PCB | ±2℃ | |
Data storage | Process Data and status storage(80GB) | |
Nozzle plate | Aluminum Alloy Plate | |
Abnormal Alarm | Abnormal temp. (over-temp/low temp.) | |
Board dropped alarm | Light Tower: Amber-warming, Green-normal, Red-abnormal | |
General | Dimension(L*W*H) | 5200×1400×1550mm |
Weight | 2200KG | |
Color | Computer grey |